Product Details:
Payment & Shipping Terms:
|
Multiple Protection: | Lightning Strike, Surge Protection | Maximum Impact Current: | 20kA Or Higher |
---|---|---|---|
Limit Voltage: | ≤500V Or Lower | Product Model: | RDK-IP08M16 |
High Light: | LCD Display Smart PDU,Under Voltage Protection Smart PDU,500V Display Smart PDU |
Power Distribution Unit , Pwer Distribution Socket Smart PDU for Power Supply
Introduction:
Power Distribution Unit(PDU) is the power distribution socket for cabinets, it is a product designed to provide power distribution for cabinet-mounted electrical equipment. It has various series specifications with different functions, different installation methods and different socket combinations, and can provide suitable rack-mounted power distribution solutions for different power environments. The application of PDU can make the power distribution in the cabinet more clean, reliable, safe, professional and beautiful, and make the maintenance of the power supply in the cabinet more convenient and reliable.
Features:
Control function: The independent eight circuits switch can be remotely controlled on and off status and reset;The independent eight circuits switch can be powered on at the same time or in a delayed sequence (optional).
Measurement: The main and each circuit of voltage, current, power, electric energy, power factor measurement.
Alarm protection: The main circuit and independent eight circuits have over-current protection, over-voltage and under-voltage alarm protection.
Debugging method: Built-in Bluetooth communication interface, debugging through Wechat mini Program.
Communication method: RS485, Modbus, Network port, LoRaWan, NB-IoT, CAT1 (4G), Bluetooth.
Cascade: RS485 can be cascaded up to 256 units.
Filter protection: With fine filter protection, output ultra-stable pure power.
Interface protection: Two-pole photoelectric isolation RS485 interface anti-jamming protection;
Alarm display: LCD screen, digital current display and full current monitoring with alarm function;
Multiple protection: Lightning strike, surge protection;
Maximum impact current: 20kA or higher;
Limit voltage: ≤500V or lower.
Specification:
Item | Specification | |
Product Name | PDU | |
Product Model | RDK-IP08M16 | |
Input | Rated input voltage | AC220V 50/60 Hz |
Max load current | 16A | |
Power supply type | Single phase input, National standard C20 socket | |
Input parameter collection | Current, voltage, active energy, power (active power, reactive power, apparent power, power factor) | |
Output | Output socket | Eight circuit; National standard 10A socket |
Rated output voltage | AC220V 50/60 Hz | |
Rated output current | 10A | |
Output parameter collection | Current, power, power factor | |
Display | LCD | Backlit text LCD display |
Port parameter | RJ45(NET) | 10/100M, Ethernet access interface |
Cascade port | 2 RS485 ports for equipment cascade (photoelectric isolation) | |
Sensor port | 2 temperature and humidity sensor interfaces | |
Other parameter | Button |
2 LCD display up/down buttons 1 LCD display down button One is used as a restart and reset button, single press the device to restart;Long press is the reset function, the device parameters are restored to factory settings. |
Working environment | Temperature | -15°C---50°C |
Relative humidity | 10—90% | |
Dimension | Black 19 inch 1U chassis | 485mm X 250mm X 44mm |
The front of the device
The back of the device
Applications:
Industrial automation control power management
1. Automatic control of factory power
2. Automatic control of traffic power
3. Automatic control of lighting advertising power
4. Automatic control of power supply in the burning room
5. Automatic control of air conditioner power supply
Data center power management
1. Enterprise Computer Center
2. IDC network data center
3. Financial Computer Center
4. School Computer Center
5. Telecom Computer Center
6. Government Computer Center
7. Military Unit Computer Center