Product Details:
Payment & Shipping Terms:
|
Voltage: | 3* 220V/380V | Current: | 3*10(100)A |
---|---|---|---|
Frequency: | 50Hz | Accuracy Class: | Reactive: 2.0 Active: 1.0 |
Pulse Constant: | 3*1600imp/kwh | Communication Mode: | PLC, Wifi, GPRS, RS485, Carrier Module |
Data Storage Period: | More Than 10 Years | Life Span: | 10 Years |
Display: | 6+2; 5+1 | Power Consumption: | Less Than 2.0W |
High Light: | domestic electric meter,digital smart meter |
Summary:
DTZY150-Z three phase four wires remote fee control smart electric meter is a intelligent electric metering product which made of large scale integrated circuit, with Digital sampling processing technology and SMT craft.
It is compatible with IEC 62053-21 <Part 21L Static meters for active energy classes 1 and 2>,and meet with DL/T645–2007 <Multi function static meter communication protocol> requirements.
Main Features:
● Metering
● Tariff
● Loadprofile
At least 4 loadprofile channels,Recordat least 490days data when time interval is 30 minutes
● Remote ON/OFF Control
Remote ON/OFF control through background software, senior password authorization needed.
● Optical port interface
Support IEC62056-21protocol, 1200bps for communication
● RS-485 serial interface
SupportIEC62056(DLMS/COSEM) protocol, 2400bps for communication
● LCD display
Number of digits value field Up to 8
Digit size 6x14.5mm
● Inputs and outputs
Optical test outputs active energy and reactive energy
● Communication modules(optional)
GPRS module:EGSM900/DCS1800 dual-band,support GSM/GPRSphase2/2+ protocol
PLC module: according to Technology Standards of SSC163X ,centerfrequency 270K, FSK modulate technolgy
● Energy Measurement
Total and time-sharing forward active & reactiveenergy measurement
Total and time-sharing reverse active & reactive energymeasurement
Total forward & reverse apparent energy measurement
Save last one to sixteen months energy data
● Max. Demand Measurement
Measure total and time-sharing forward active &reactive maximum demand and time of occurred
Measure total and time-sharing reverse active &reactive maximum demand and time of occurred
Measure total forward & reverse apparent maximumdemand and time of occurred
● Real Time Measurement
Real-time measurement of the phase voltage, current,total active power,
reactive power, apparent power, total power factor, powergrid frequency
● TOU
4tariffs, 100holidays, 14season‐tables, 8time zone‐tables, each table onmaximum 14 time zones
● Event Log
The last 10 records of following events:Power-down,Programing, Cover opening, Terminal cover opening, Reverse power,
PhaseFail.the records include data and time
Main Parameter:
Item | Specification | |
Reference Current | 1.5(6)A 5(40)A 5(60)A 15(60)A 20(100)A | |
Reference Voltage | 3×220V/380V | |
Dimension (mm) | 290×170×85 | |
Working Voltage Range | 0.8Un~1.15Un | |
Maximum Working Voltage | 0.7Un~1.2Un | |
Working Temperature | -25℃~+60℃ | |
Maximum Working Temperature | -40℃~+70℃ | |
Accuracy | Active 1.0 | Reactive 2.0 |
Relative Humidity | ≤95% | ||||||
Frequency | (45~60)Hz | ||||||
Start Present | Direct Mode 0.004In; | ||||||
CT Mode: 0.002In | |||||||
Consumption | <1.5W,10VA |
Factory setting subject to nameplate | ||||||||
For 1.5(6)A meter: Active | 6400imp/kW·h | |||||||
Reactive | 6400imp/kvar·h | |||||||
For 5(40)A meter: Active | 600imp/kW·h | |||||||
Constant | Reactive | 600imp/kvar·h | ||||||
For 5(60)A /15(60)A meter: Active | 400imp/kW·h | |||||||
Reactive | 400imp/kvar·h | |||||||
For 20(100)A | meter: | Active | 300imp/kW·h | |||||
Reactive | 300imp/kvar·h | |||||||
Pulse Width | (80±20)ms |
Clock Error | ≤0.5 s/d | 0℃~+40℃:±2ppm; | ||
-40℃~+85℃: ±3.5ppm | ||||
Clock Frequency | 1Hz | |||
Battery Life | 10 year | |||
Battery Continuous Working Period | ≥5 year |