Product Details:
Payment & Shipping Terms:
|
Up Link: | GPRS Or RS232 | Down Link: | PLC Or RS485 |
---|---|---|---|
Power Supply: | AC 3*220V/380V | Feature: | Data Communication Unit |
Display: | LCD | ||
High Light: | Remote Meter Reading System,Electric Meter Reading System |
Data Concentrator Automatic Meter Reading System Three Phase Power Supply GPRS
DJGZ32-RDK15 intelligent data concentrator is one important part of AMI system. It connects with master station as a gateway for communication between the meters and the HES. It can perform task setting, data collection, data transmission and data storage, meter management, and task execution .
The upper communication between data concentrator and master station employs GPRS or RS232 technology; the Down link communication between data concentrator and the meters employs RS485/PLC communication.
Main Features
1) GPRS uplink with head-end server (HES)
2) Alternative com port :IR optical and RS485
3) On demand and scheduled meter readout
4) Remote load control overriding the consumers
5) Non-volatile memeory for data retention
6) IEC 62056-21 and DLMS/COSEM compliant
7) Automatic fault alarm to HES
Utility benefits
1) High capacity for a hub of up to 500 pcs sub-meters
2) Surge protection and low voltage operatable
3) Quick and easy to install
4) Low operational and maintenance cost
5) Remote tariff setting, time synchronization with meters
6) Long life time design with easy upgrade features
Specifications:
Electrical parameters: | |
Voltage | |
Nominal voltage Un | 220V/380V |
Extended operating voltage range | 80%~115%Un |
Limited voltage | 60%~130%Un |
Frequency | |
Nominal frequency fn | 50Hz |
tolerance | -6%~2% |
Current | |
Basic current(Ib) | 1.5(6)A |
Maximum current(Imax) | 10A |
Starting current(Ist) | 3mA |
Active energy constant | 6400imp/kWh |
Measurement Accuracy | |
Active energy | 1% |
Reactive energy | 2% |
Power Consumption | |
Power consumption in Voltage circuit | <10W <8VA |
Power consumption in current circuit | <1VA |
Temperature range | |
Working temperature | -35℃ to+70℃ |
Limited working temperature | -40℃ to+75℃ |
Insulation strength | |
AC Insulation strength | 4kV at 50Hz during 1min |
Impulse voltage 1.2/50μs mains connections | 8kV |
Electro Magnetic Compatibility | |
Electrostatic discharges | |
Contact discharge | 8kV |
Air discharge | 16kV |
Electromagnetic RF fields | |
27MHz to 500MHz typical | 10V/m |
100kHz to 1GHz typical | 30V/m |
Fast transient burst test | 4kV |
Mechanical requirements | |
Meter shell Protection Rate | IP51 |
Protection |