Product Details:
Payment & Shipping Terms:
|
Name: | Energy Meter Single Phase | Accuracy Class:: | 1.0; 2.0 (positive And Reverse Active) |
---|---|---|---|
Pulse Constant:: | 3200 Imp/kwh | Indicator: | Pulse Output; Power Off Indication |
Data Storage Period: | More Than 10 Years | Voltage: | 220V/230V/240V |
Current: | 5(40)A | Clock Accuracy: | Less Than 0.5S/day |
High Light: | smart energy meter,active energy meter |
Smart Card Sinlge Phase Prepaid Energy Meter Sinlge Phase Two Wires with Remaining Credit Display
DDSY150 series electronic single phase watt hour meter is a high technology product adople avanced IC technology as well as SMT technology, both circuit design and componects selectior are up to various working environment to guaranty that power meter can operate steadily for a lor time. The finished meter don't neet to be adjusted so that the calibration cycle is long. It extremely reduce the labor force of the electricity board for calibrating power meters. The feature of the products are anti-thief, long life, high accuracy, high reliability, low power consumption small volume, light weight, the meter is up to the according to iec 1036-96 and GB/t17215-200 standard.
1. Main Features:
1.1. Standard IC card hardware-based cryptographic for prepayment, the power supply department receives the electric charge in advance by means of vending the power utilization card (IC card), and users should buy first for power utilization.
1.2. It integrates full-digital metering with using electricity power consuming display, prepayment control, reading card and intelligent anti-power stolen, ect., has high reliability.
1.3. Function of overload protection. When the load exceeds the preset maximum current for a continuous period, it would cut off the power supply circuit automatically, nixie tube would display warning symbol flickeringly, and the watt-hour meter would switch off automatically after a certain period of time delay.
1.4. The power utilization IC card is treated with software and hardware-based cryptographic, guaranteeing safety, correctness and reliability of data. Through special design, the IC card records the residual and cumulated electric quantity of meter as well as information about electricity-stolen if there is while user inserts the card.
1.5. Perfect card interface protection circuit, preventing hostile attack behaviors effectively.
1.6. Display of residual electric quantity, it displays in 6-digit (5 integral numbers, 1 decimal number).
1.7. When the residual electric quantity reaches the prep warning value, nixietube would display the residual electric quantity, reminding users to input new electricity purchasing quantity.
1.8. When the residual electric quantity in watt-hour meter remains zero, the watt-hour meter would trip automatically, and cut off the power supply, at this moment, users must bring the card and go to power vending department to purchase electricity (power supply department could set a certain quantity for overdrawing, insert the card, users could use a certain quantity of electricity), only when inserting the card with effective electric quantity into the meter that it could supply power normally.
1.9. The power would be cut off automatically when the owed electric quantity reaches a certain degree, input new electricity purchasing quantity (after deducting the over-consumed electricity), the power supply would be recovered automatically.
1.10. Application of magnetic latching relay not only improves reliability of power interruption operation, reduces power consumption after power off, but also conquers the shortcoming of relay of contacts adhesion when working for long time at heavy current.
1.11. When coming across power failure, it would store the data automatically, and resume data at power recovery.
1.12. Computer, special IC card read-write device and charging management software form the electricity vending management system.
1.13. Carry out comparative analysis to the recorded information, the management system is able to list out users suspected of electricity stealing action for concentrated investigation, reducing the working capacity of anti-electricity stolen and electricity stolen investigation.
1.14. If the watt-hour meter is reversed connected, it still is able to meter correctly.
2. Technical Parameters:
① Applicable standard: IEC 1036, GB/T18460-2001.
② Rated Voltage: 220V, (extreme operating volatge: 70%~190%)
③ Rated Current:5(20)A, 5(40)A,10(40)A, 5(60)A, 10(60)A ,15(60)A ;
④ Rated frequency: 50/60Hz
⑤ Pulse Constant: ,3200,1600,800 imp/kW.h
⑥ .Accuracy Class: 1.0, 2.0;
⑦ Overall Consumption: < 1.3W
⑧ Starting Current: ≤0.4%Ib
⑨ Anti-creeping: logical anti-creeping;
⑩ Data Storage: 10 years even being powered off
⑪ Lifetime: >10 years
⑫ Weights: About 0.6kg
⑬ Dimension: 136mm×109mm×60mm
Rated Current | 5(20),5(30),10(40),15(60),20(80),30(100) |
Rated voltage | 220 or 240 |
Rated frequency | 50 or 60 |
Accuracy | Class 1 or Class 2 |
item | technical parameter |
Precision grade | Active power 1.0 grade,2.0grade |
Reference voltage(Un) | 220V |
Reference current(In) | 5(40)A,10(60)A,20(100)A |
Reference frequency | 50Hz |
Working voltage range | stipulated working voltage range:0.9Un~1.1Un |
Expanded working voltage range:0.8Un~1.2Un | |
Working temperature range | stipulated working voltage range:-25ºC ~+55ºC |
limited working voltage range:-40ºC ~+70ºC | |
Storage and transportation limited temperature range:-40ºC ~+70ºC | |
Power consumption | Voltage circuit:≤2W/5VA;current circuit:≤1VA |
OEM-ODM Service Offered
1.Material,size and other requirements of Led Traffic Signal Light can be customized.
2.Please kindly inform us which items you are interested & the reasonable price will be provided you upon receipt of your new inquiry ASAP.
3.Answer your question detailed.
4.Solve the problem with you during using our products.
Safety precautions:
* Use only isolated tools.
* Do not connect the meter to a 3 phase - 415V AC - network.
* Place the meter only in dry surroundings.
* Make sure the used wires are suitable for the max current the meter can measure.
* Make sure the AC wires are installed correctly before activating the current/voltage.
* Do not touch the meter connecting clamps directly with your bare hands, with metal, blank wire or other material as you will have the chance of an electricity shock and a possible chance for health damage.
Contact Person: Mrs. Ada Yang
Tel: 86 15623095278
Fax: 86-27-84967521