Product Details:
Payment & Shipping Terms:
|
| Refer. Voltage: | 3*100V | Refer. Current: | 3*1.5(6)A |
|---|---|---|---|
| Pulse Constant: | 3*6400imp/kwh | Multi Tariff: | 4 Tariffs |
| Life Time: | More Than 10 Years | Theory: | 3 Phase 3 Wire Energy Meter |
| Highlight: | three phase energy meter,three phase smart meter |
||
RS485 Three Phase Electric Meters 3P3W Energy Meter Multi Tariff Active Energy Measure
The 3P meter integrates high precision metrology with diversity of wireless communication technology completed in a plug & play module unit, allowing it to be utilized as element of AMR AMI solution. It operates in three phase four wire and three wire network. And it is with anti-tamper functions and completed in a BS 5685 footprint case. The meter is mainly used for commercial and inustrial environments.
The meter works with a modular design of wireless communication. A utility and service provider can select from various communication modules to setup their AMR AMI facilities. The module unit is replaceable and easy to repair.
Featured functions
■Active and reactive energy measurement in both directions
■ Load profiling and Maximum demand recording at programmable intervals
■Flexible swap between credit and prepayment mode
■ Full spectrum of metrological measurement of V, A, P, PF, etc.
■Available for both direct and CT/VT connection
■Available for both four wires and three wires network
■Adjustable power limit
■Optical and RS485 com port
User benefits
1) All-in-one instrumentation
2) Low operational and deployment cost
3) Allows for multi-rate and usage register on TOU basis
4) Setting for tariff, emergency unit, load limit, surchages, debt collection, etc.
5) Anti-tamper: earthing, cover open, bypass, etc
6) Broad metrological range to reduce inventory cost
Specifications:
|
Electrical parameters |
|
|---|---|
|
Nominal voltage Un |
3x 220/230/ 240V |
|
Limited voltage |
60%~120%Un |
|
Frequency |
50/60Hz+5% |
|
Basic current(Ib) |
5A |
|
Maximum current(Imax) |
100A |
|
Starting current(Ist) |
30mA |
|
Active energy constant |
400imp/kWh |
|
Accuracy |
|
|
Active energy to IEC62053‐21 |
Class1.0 |
|
Reactive energy to IEC62053‐23 |
Class2.0 |
|
Power Consumption |
|
|
Power consumption in Voltage circuit |
<2W <8VA |
|
Power consumption in current circuit |
<1VA |
|
Temperature range |
|
|
Operation meter |
25℃ to+70℃ |
|
Storage |
40℃ to+85℃ |
|
|
|
|
Insulation strength |
|
|
AC Insulation strength |
4kV at 50Hz during 1min |
|
Impulse voltage 1.2/50μs mains connections |
8kV |
|
|
|
|
Electro Magnetic Compatibility |
|
|
Electrostatic discharges |
|
|
Contact discharge |
8kV |
|
Air discharge |
16kV |
|
Electromagnetic RF fields |
|
|
27MHz to 500MHz typical |
10V/m |
|
100kHz to 1GHz typical |
30V/m |
|
Fast transient burst test |
4kV |
|
Mechanical requirements |
|
|
Protection Rating |
IP54 |
|
Insulation Classification |
Protective Class II |
|
Maximum cable size |
10 mm |
Contact Person: Mrs. Ada Yang
Tel: 86 15623095278
Fax: 86-27-84967521