| Product Details: 
 Payment & Shipping Terms: 
 | 
| Refer. Voltage: | 3*100V | Refer. Current: | 3*1.5(6)A | 
|---|---|---|---|
| Pulse Constant: | 3*6400imp/kwh | Multi Tariff: | 4 Tariffs | 
| Life Time: | More Than 10 Years | Theory: | 3 Phase 3 Wire Energy Meter | 
| Highlight: | three phase energy meter,three phase smart meter | ||
RS485 Three Phase Electric Meters 3P3W Energy Meter Multi Tariff Active Energy Measure
The 3P meter integrates high precision metrology with diversity of wireless communication technology completed in a plug & play module unit, allowing it to be utilized as element of AMR AMI solution. It operates in three phase four wire and three wire network. And it is with anti-tamper functions and completed in a BS 5685 footprint case. The meter is mainly used for commercial and inustrial environments.
The meter works with a modular design of wireless communication. A utility and service provider can select from various communication modules to setup their AMR AMI facilities. The module unit is replaceable and easy to repair.
      Featured functions
■Active and reactive energy measurement in both directions
■ Load profiling and Maximum demand recording at programmable intervals
■Flexible swap between credit and prepayment mode
■ Full spectrum of metrological measurement of V, A, P, PF, etc.
■Available for both direct and CT/VT connection
■Available for both four wires and three wires network
■Adjustable power limit
■Optical and RS485 com port
User benefits
1) All-in-one instrumentation
2) Low operational and deployment cost
3) Allows for multi-rate and usage register on TOU basis
4) Setting for tariff, emergency unit, load limit, surchages, debt collection, etc.
5) Anti-tamper: earthing, cover open, bypass, etc
6) Broad metrological range to reduce inventory cost
Specifications:
 
| Electrical parameters | |
|---|---|
| Nominal voltage Un | 3x 220/230/ 240V | 
| Limited voltage | 60%~120%Un | 
| Frequency | 50/60Hz+5% | 
| Basic current(Ib) | 5A | 
| Maximum current(Imax) | 100A | 
| Starting current(Ist) | 30mA | 
| Active energy constant | 400imp/kWh | 
| Accuracy | |
| Active energy to IEC62053‐21 | Class1.0 | 
| Reactive energy to IEC62053‐23 | Class2.0 | 
| Power Consumption | |
| Power consumption in Voltage circuit | <2W <8VA | 
| Power consumption in current circuit | <1VA | 
| Temperature range | |
| Operation meter | 25℃ to+70℃ | 
| Storage | 40℃ to+85℃ | 
| 
 | |
| Insulation strength | |
| AC Insulation strength | 4kV at 50Hz during 1min | 
| Impulse voltage 1.2/50μs mains connections | 8kV | 
| 
 | |
| Electro Magnetic Compatibility | |
| Electrostatic discharges | |
| Contact discharge | 8kV | 
| Air discharge | 16kV | 
| Electromagnetic RF fields | |
| 27MHz to 500MHz typical | 10V/m | 
| 100kHz to 1GHz typical | 30V/m | 
| Fast transient burst test | 4kV | 
| Mechanical requirements | |
| Protection Rating | IP54 | 
| Insulation Classification | Protective Class II | 
| Maximum cable size | 10 mm | 