Send Message
Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
News
WUHAN RADARKING ELECTRONICS CORP.
Home ProductsThree Phase Electric Meter

Light Weight Three Phase Electric Meter With Active / Reactive Energy Measurement

China WUHAN RADARKING ELECTRONICS CORP. certification
China WUHAN RADARKING ELECTRONICS CORP. certification
Really profession in the meter industry, gave us so many useful advice in the AMI solution, very good!

—— George

The meters are good, simple but useful, and also good in after service, each of my question or requirement can be solved well! Thank you for cooperate

—— Amitansu

I'm Online Chat Now

Light Weight Three Phase Electric Meter With Active / Reactive Energy Measurement

Light Weight Three Phase Electric Meter With Active / Reactive Energy Measurement
Light Weight Three Phase Electric Meter With Active / Reactive Energy Measurement Light Weight Three Phase Electric Meter With Active / Reactive Energy Measurement

Large Image :  Light Weight Three Phase Electric Meter With Active / Reactive Energy Measurement

Product Details:
Place of Origin: Made In China
Brand Name: Radarking
Certification: IEC62053-21; IEC62052-11; IEC62053-23;
Model Number: DTS150
Payment & Shipping Terms:
Minimum Order Quantity: 100
Price: Negotiate
Packaging Details: Standard Package
Delivery Time: 35days
Payment Terms: Western Union, T/T, L/C, MoneyGram
Supply Ability: 5000000 pcs per year
Detailed Product Description
Reference Voltage: 3* 220V/380V Reference Current: 3*20(80)A
Rated Frequency: 60Hz/50Hz Display: Digital Only
Standard: IEC62053-21; IEC62052-11; IEC62053-23 Accuracy Class: Active 1.0; Reactive 2.0
High Light:

three phase power meter

,

three phase smart meter

LCD Display Three Phase Electric Meters with Active & Reactive Energy Measurement

 

1. INTRODUCTION: 

 

Three-phase Active&Reactive Energy Meter adopts the advanced special energy measuring chips and the multi-rate technology, using the date sampling and SMT technology. The product is designed and produced according to the practical situation of the dweller. All the elements inside the meter have the feature of long-life, high-reliance.

 

2. MAIN FEATURES:

Energy Measurement


Total and time-sharing forward active & reactiveenergy measurement
Total and time-sharing reverse active & reactiveenergy measurement
Total forward & reverse apparent energy measurement
Save last one to sixteen months energy data

Max. Demand Measurement
Measure total and time-sharing forward active &reactive maximum demand and time of occurred
Measure total and time-sharing reverse active &reactive maximum demand and time of occurred
Measure total forward & reverse apparent maximumdemand and time of occurred

Real Time Measurement
Real-time measurement of the phase voltage, current,total active power, reactive power, apparent power, total power factor, powergrid frequency

TOU
4tariffs, 100holidays, 14season‐tables, 8time zone‐tables, each table onmaximum 14 time zones

Optical port interface
Support IEC62056-21protocol

RS-485 serial interface
Communication standards DL/T645-2007, 2400bps forcommunication
SupportIEC62056(DLMS/COSEM) protocol

LCD display
Number of digits value field Up to 8
Digit size 6x14.5mm

 

3. TECHNICAL SPECIFICATION:

Comprising Table of Model And Impulse Constant (the specification constant value is subject to the nameplate)

 

Model

Reference Voltage

(V)

Reference Current

(A)

Impulse Constant

(imp/kWh)

DTS150 3×230V/400V 3×5 400

 

Accuracy Class: Class 0.5

Rated Frequency: 50Hz

Starting Current: ≤0.005Ib

Creeping: Anti-creeping design

Dimension: 245mm×150mm×78mm

Weight: 1.5kg

Lifetime: ≥10 years

 

Electrical Parameters

 

Normal Operating Voltage 3×230V/400V
Limit Operating Voltage 1.2Un

Voltage Circuit Consumption

 

≤0.5W*3

Current Circuit Consumption

 

<2VA*3

 

Climate Conditions

Normal Operating Temperature -35~+80 ℃
Limited Operating Temperature -40~+85℃
Storage And Transportation Temperature -40~+85℃
Storage And Operating Humidity ≤85%H

 

4. INSTALLATION AND CONNECTION: 

1. The meter shall be installed in the dry area with good ventilation condition to ensure safety and reliability during installation and operation. If the meter shall be installed in the area with dirty and easily gets damaged, the metering box should be configured to protect meter against the dirty environments.
 
2. The dimension of meter is as below: the holes should be digged ahead accord with the size and the meter bottom should be fixed on the strong, fire-proof subjects.

 

 
Light Weight Three Phase Electric Meter With Active / Reactive Energy Measurement 0

 

Safety precautions:
* Use only isolated tools.
* Place the meter only in dry surroundings.
* Make sure the used wires are suitable for the max current the meter can measure.
* Make sure the AC wires are installed correctly before activating the current/voltage.
* Do not touch the meter connecting clamps directly with your bare hands, with metal, blank wire or other material as you will have the chance of an electricity shock and a possible chance for health damage.
* Make sure the protection cover is placed after installation and has been sealed.
* Installation, maintenance and repair should only be done by a certified electrician.
* Never break the seals or open the front cover as this might influence the functionality of the meter.
* Do not through, drop, kick or other physical violence to the meter as there are high precision components inside that will break or make the meter measure inaccurate.
* Do not mount the meter in area's with harm gas, dust, mildew or insects or on unstable surfaces.

Contact Details
WUHAN RADARKING ELECTRONICS CORP.

Contact Person: Mrs. Ada Yang

Tel: 86 15623095278

Fax: 86-27-84967521

Send your inquiry directly to us (0 / 3000)